Optical Nerve Sheath Diameter (ONSD) Ultrasonography as Intracranial Non-Invasive Pressure Measurement in Post–Operative Patient EDH Evacuation in ICU

Ramadhan Saputro, Resa Putra Adipurna, Buyung Hartiyo Laksono

Abstract


Intracranial Pressure (ICP) monitoring is an important component in the management of severe Traumatic Brain Injury (TBI) in ICU. Periodic ICP monitoring in patients with severe TBI who were treated in ICU resulted in lower mortality rates than those who were not measured. ICP can be measured by invasive or non-invasive methods. Invasive measurements related to higher cost, while non-invasive tests such as MRI and CT scans are associated with radiation exposure. ONSD ultrasound is an alternative examination that is practical, inexpensive, without radiation, and can be performed bedside. We report a case in the ICU of RSUD Dr. Saiful Anwar Malang, male, 44 years old, had a traffic accident, and was diagnosed with severe TBI with GCS E2V2M4, right frontotemporal 36cc epidural hematoma, cerebral edema, and left posterolateral 4th rib fracture. The patient underwent epidural hematoma surgical evacuation. Postoperatively, the patient was treated in ICU. We performed periodic ONSD ultrasound and with the guidance of these examinations the patient's management could be adjusted. Within 48-hours postoperatively the patient could be extubated and then moved to ward. ONSD ultrasound could be done bedside so that clinicians could quickly and precisely adjusted the management according to the dynamic condition of the patient.

Keywords


ICP Monitoring, Intensive Care Unit (ICU), Optical Nerve Sheath Diameter (ONSD), Severe Traumatic Brain Injury (TBI), Ultrasonography (USG)

Full Text:

PDF

References


Shen L, Wang Z, Su Z, Qiu S, Xu J, Zhou Y, et al. Effects of intracranial pressure monitoring on mortality in patients with severe traumatic brain injury: a meta-analysis. PLoS One. 2016;11(12):e0168901. Published 2016 Dec 28. Doi:10.1371/journal.pone.0168901

Marklund N. The neurological wake-up test-a role in neurocritical care monitoring of traumatic brain injury patients?. Front Neurol. 2017;8:540. doi:10.3389/fneur.2017.00540

Raboel PH, Bartek J Jr, Andresen M, Bellander BM, Romner B. Intracranial pressure monitoring: invasif versus non-invasif methods-a review. Crit Care Res Pract. 2012;2012:950393. Doi: 10.1155/2012/950393

Wang LJ, Yao Y, Feng LS, Wang YZ, Zheng NN, Feng JC, et al. Noninvasif and quantitative intracranial pressure estimation using ultrasonographic measurement of optic nerve sheath diameter. Sci Rep. 2017;7:42063. Doi:10.1038/srep42063

Stead GA, Cresswell FV, Jjunju S, Oanh PKN, Thwaites GE, Donovan J. The role of optic nerve sheath diameter ultrasound in brain infection. eNeurologicalSci. 2021;23:100330. Doi: 10.1016/j.ensci.2021.100330.

Soldatos T, Chatzimichail K, Papathanasiou M, Gouliamos A. Optic nerve sonography: a new window for the non-invasif evaluation of intracranial pressure in brain injury. Emerg Med J. 2009;26(9):630–4. Doi: 10.1136/emj.2008.058453.

Williams P. Optic nerve sheath diameter as a bedside assessment for elevated intracranial pressure. Case Reports in Critical Care. 2017;(1):1–2. Doi: https://doi.org/10.1155/2017/3978934

Oddo M, Crippa IA, Mehta S, Menon D, Payen JF, Taccone FS, et al. Optimizing sedation in patients with acute brain injury. Crit Care. 2016;20(1):128. Doi:10.1186/s13054-016- 1294-5

Zhu S, Cheng C, Zhao D, Zhao Y, Liu X, Zhang J. The clinical and prognostic values of optic nerve sheath diameter and optic nerve sheath diameter/eyeball transverse diameter ratio in comatose patients with supratentorial lesions. BMC Neurol. 2021;21(1):259.

Betcher J, Becker TK, Stoyanoff P, Cranford J, Theyyunni N. Military trainees can accurately measure optic nerve sheath diameter after a brief training session. Mil Med Res. 2018;5(1):42.




DOI: https://doi.org/10.24244/jni.v14i1.582

Refbacks

  • There are currently no refbacks.


                                    

 

JNI is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License